Step
|
Notes
|
1
|
Press [Max Inactive Ch Limit].
|
|
2
|
Press [Limits].
|
Enables you to toggle the Maximum Inactive Channel measurement's high limit function On (active) and Off (inactive).
- If set to On, the displayed Maximum Inactive Channel metrics will change from blue to red (fail), or to green (pass), and will indicate either "P" (pass) or "F" (fail). If the measured value falls above the high limit, the words 'ALL PASS' in the bar at the bottom of the screen will change to 'FAILURE'.
- If set to Off, the Maximum Inactive Channel power value will be displayed in blue. The bar at the bottom of the screen will indicate measurement in progress.
|
3
|
Set the high MAC limit.
- [High MAC Limit]
- Enter the number on the numeric keypad.
- [Enter]
|
High Limit range: -200 to 200 dB
|
4
|
Set the high Pilot limit.
- [High Pilot Limit]
- Enter the number on the numeric keypad.
- [Enter]
|
High Limit range: -200 to 200 dB
|