Setting Average, Sweep, and Restart


Setting the Sweep

You can select either continuous or single sweep. Continuous sweep provides repeated, ongoing measurements. Single sweep performs a single measurement that is repeated only when you push the Single button.
To set sweep:

Step
Notes
1
[Average/Sweep]

2
[Continuous] or [Single]
Each time you press this softkey, the selected option changes.

Setting Averaging

You can choose to have averaging on or off and set the number of averages you want to take. Averaging only applies to the data, not the trace. You can select from the following types of averaging:
To set averaging:

Step
Notes
1
Set the number of averages.
a. [Average]
b. Enter the number of averages using the numeric keypad.
c. [Enter]

2
Select the type of averaging you want to apply.
a. [Average/Sweep]
b. [Averaging]
c. [Off], [Running Average], [Max Hold], [Group Average], or [Group Max Average]



NOTE: These two steps can be performed in any order. However, if you turn averaging on and a large number of averages has previously been set, there may be a delay before you can change number of averages.

Setting Restart

When you have averaging turned On and you are in Continuous Sweep mode, you can restart the averaging by pressing the Restart menu key. The Restart key has no effect if you are in Single sweep mode.
To restart averaging:

Step
Notes
1
[Average/Sweep]

2
[Restart]
This key is unavailable or has no effect when Sweep is set to Single. To restart a Single Sweep measurement, press [Single].