Setting the PN Increment


The PN Increment allows you to choose the increment step for the PN Offset. Typically the PN Increment is set to 1 when measuring CDMA transmitter performance while connected to the base station via RF cable.
The PN Increment field enables you to search based on a step size of your choice. If PN Increment = 1 (default), the search will step through PN values by one PN at a time. If PN Increment = 5, it will step through PN values 0, 5, 10, and so on. The Measured PN displayed will be a multiple of 5, even if the actual PN is not a multiple of 5. If you know that all base stations in the area have fixed increments, then set the PN Increment field to that increment value. If you don't know, then use the default value of 1.

Step
Notes
1
[PN Inc]

2
Enter the PN Increment using the numeric keypad.
The maximum value you can enter is 15.
3
[Enter]
Notice (and verify) that the number you entered for your chosen PN Increment number appears below the PN Inc text on the corresponding button.