Setting Auto Mode Bar Count


The Measurement Bar Count setting allows you to alter the number of channel data bars displayed when you set the [Scan Mode] to Auto. The channels that have the highest power will be displayed, up to the number of channels you have set.
If you set you Start Freq mode to Chan, your E7495 test set displays only one channel, so your Auto Mode Bar Count is automatically set to 1. If you later set your Start Freq mode to Freq so you can display several channels, your Auto Mode Bar Count setting will stay at 1. You will need to change Auto Mode Bar Count manually if you want to display more than one channel, or set your Scan Mode to Range or to List.
To Set the Measurement Auto Mode Bar Count:

Step
Notes
1
[Setup]

2
[Auto Mode Bar Count]

3
Enter the number of bars to display using the numeric keypad, the up and down arrows, or the knob.
The maximum number of bars that can be displayed is 20.
4
[Enter]
If you use the up and down arrows or the knob to change the bar count number, the Enter key will not be displayed. However, the display will update to the entered number of bars after a few seconds.