Setting Channel Scanner Power Limits


You can set upper and lower Channel Scan Power Limits to determine which of the channels scanned are valid. Channels whose power falls within your specified limits are displayed in green on your graphics display, and are further indicated with a "P" for "Pass". Channels whose power either falls below the lower limit, or exceeds the upper limit, are displayed in red on your graphics display, and are indicated with an "F" for "Fail". A pass or fail of this Channel Scanner Power Limit does not affect the summary status message. If Channel Power Limits are set to Off, the channels are displayed in blue on the screen, and no Pass/Fail indicator is shown.
If Chan Scan Pwr Limits are set to On, the limits you specified are represented on the graphics display with two yellow lines. The High Limit line is indicated with "H>", and the Low Limit line with "<L".
To Set the Channel Scan Upper and Lower Limits:

Step
Notes
1
[Setup]

2
[Chan Scan Pwr Limits]

3
[Limits]

4
[On] or [Off]

5
Set the upper limit.
  1. [High Limit]
  2. Enter the number on the numeric keypad.
  3. [dBm]
The limit is specified in dBm.
6
Set the lower limit.
  1. [Low Limit]
  2. Enter the number on the numeric keypad.
  3. [dBm]
The limit is specified in dBm.