Setting TS Power Limits


You can set upper and lower Timeslot Power Limits for your TS Power Measurement results.
If TS Power Limits are turned On, and your measured TS power is within the limits you have specified, the numeric results reported in the metrics portion of the screen will be displayed in green, and the Limit Pass will be indicated by "(P)" after the results. If your measured TS Power is outside your specified limits, the numeric results reported in the metrics portion of the screen will be displayed in red, and the Limit Failure will be indicated by "(F)" after the results.
To Set the TS Power Limits:

Step
Notes
1
[Setup]

2
[TS Pwr Limits]

3
[Limits]

4
[On] or [Off]

5
Set the upper limit.
  1. [High Limit]
  2. Enter the number on the numeric keypad.
  3. [dBm]

6
Set the lower limit.
  1. [Low Limit]
  2. Enter the number on the numeric keypad.
  3. [dBm]